| Voltage/Frequency | 4000V ± 10%/60 Hz 4000V ± 10%/60 Hz | 
| Type of EX-Protection | Class 1 Division 2, Group A,B,C,D T3 (NEC or CEC) Class 1 Division 2, Group A,B,C,D T3 (NEC or CEC) | 
| Electric Motor Type | Squirrel Cage Induction Motor Squirrel Cage Induction Motor | 
| Mounting Designation | F1 or F2 F1 or F2 | 
| Number of Poles | 8 8 | 
| Full Load Speed | 894 r/min 894 r/min | 
| Connection of Stator Winding | Star Star | 
| Rated Torque | 29366 lb/ft 39815 N·m | 
| Standards | NEMA MG1 NEMA MG1 | 
| Maximum Altitude - Before Derate | 3000 ft 1000 m | 
| Service Factor | 1.15 SF 1 vfd | 
| No Load Current | 200 Amps 200 Amps | 
| Maximum Ambient Temperature | 104 °F 40 °C | 
| Temperature Rise | Class B at rated load Class B at rated load | 
| Shaft | 8.5 in 216 mm | 
| Insulation | Class F Class F | 
| Enclosure Type/Method of Cooling | WP-II WP-II | 
| Duty | Continuous Continuous | 
| Locked Rotor Amps | 520% Code E 520% Code E | 
| Full Load Current | 658 Amps 658 Amps | 
| Locked Rotor Torque | 60% 60% | 
| Breakdown Torque | 190% 190% | 
Advantages and Features
Standard Equipment
- 
                        Bearings
                        
                        
                        
- Self-lubricated sleeve bearings
 
- Insulated non-drive end bearings to reduce bearing currents
 
- Bearing RTDs for temperature monitoring
 
 
- 
                        Rotors
                        
                        
                        
- Designed for minimal vibration
 
- Dynamic balancing at full operational speed
 
- Fabricated copper squirrel cages
 
- Oversized, forged, keyless shaft
 
- AISI 4140/DIN42CrMo4 shaft
 
 
- 
                        Stators
                        
                        
                        
- Radial air ducts ensure uniform and efficient cooling
 
- Vacuum pressure impregnated with specially formulated epoxy resin
 
- 2X RTDS per Phase
 
- Space heater
 
- Welded and machined stator core retains its rigidity throughout motor life to ensure a sealed and homogeneous insulation system that results in high dielectric strength, excellent heat transfer and the elimination of hazardous internal partial discharges